Researchers Develop Clinically Validated Wearable Ultrasound Patch For Continuous Blood Pressure Monitoring

De wikiDHI
Revisión a fecha de 17:31 5 sep 2025; ValE753698233480 (Discusión | contribuciones)

(dif) ← Revisión anterior | Revisión actual (dif) | Revisión siguiente → (dif)
Saltar a: navegación, buscar


The wearable ultrasound patch builds upon an earlier prototype that was pioneered by the lab of Sheng Xu, a professor in the Aiiso Yufeng Li Family Department of Chemical and Nano Engineering at UC San Diego. Researchers re-engineered the patch with two key improvements to boost its efficiency for continuous blood stress monitoring. First, they packed the piezoelectric transducers nearer together, BloodVitals SPO2 enabling them to supply wider protection so they may better goal smaller arteries such because the brachial and radial arteries, BloodVitals monitor which are more clinically related. Second, they added a backing layer to dampen redundant vibrations from the transducers, resulting in improved signal readability and monitoring accuracy of arterial walls. In checks, the system produced comparable results to a blood pressure cuff and one other clinical system known as an arterial line, which is a sensor inserted into an artery to constantly monitor blood stress. While the arterial line is the gold customary for blood stress measurement in intensive care models and operating rooms, it is extremely invasive, limits affected person mobility, BloodVitals SPO2 device and may cause ache or discomfort.



The patch provides a easier and extra reliable different, as proven in validation tests performed on patients undergoing arterial line procedures in cardiac catheterization laboratories and intensive care items. Researchers performed extensive assessments to validate the patch’s security and accuracy. A total of 117 subjects participated in research that evaluated blood pressure across a wide range of activities and settings. In a single set of assessments, seven contributors wore the patch during each day activities equivalent to cycling, blood oxygen monitor elevating an arm or leg, BloodVitals test performing mental arithmetic, meditating, eating meals and consuming energy drinks. In a larger cohort of eighty five subjects, the patch was tested throughout changes in posture, BloodVitals experience comparable to transitioning from sitting to standing. Results from the patch carefully matched these from blood pressure cuffs in all checks. The patch’s ability to continuously monitor blood stress was evaluated in 21 patients in a cardiac catheterization laboratory and four patients who were admitted to the intensive care unit after surgery. Measurements from the patch agreed closely with results from the arterial line, BloodVitals SPO2 showcasing its potential as a noninvasive alternative.



"A large advance of this work is how completely we validated this technology, thanks to the work of our medical collaborators," mentioned Xu. "Blood stress can be everywhere in the place depending on factors like white coat syndrome, masked hypertension, every day actions or use of treatment, which makes it tricky to get an correct prognosis or handle therapy. That’s why it was so essential for us to check this gadget in a large variety of actual-world and clinical settings. The analysis workforce is preparing for big-scale clinical trials and plans to combine machine learning to additional enhance the device’s capabilities. Efforts are additionally underway to validate a wireless, battery-powered model for long-term use and seamless integration with existing hospital systems. Baiyan Qi, Xinyi Yang, Xiaoxiang Gao, Hao Huang, Xiangjun Chen, Yizhou Bian, Hongjie Hu, Ray S. Wu, Wentong Yue, Mohan Li, Chengchangfeng Lu, Ruotao Wang, Siyu Qin, Isac Thomas, Benjamin Smarr, Erik B. Kistler, Belal Al Khiami, Irene Litvan and Sheng Xu, UC San Diego; and Esra Tasali and Theodore Karrison, The University of Chicago.



Issue date 2021 May. To attain extremely accelerated sub-millimeter resolution T2-weighted purposeful MRI at 7T by creating a three-dimensional gradient and spin echo imaging (GRASE) with inside-quantity choice and variable flip angles (VFA). GRASE imaging has disadvantages in that 1) ok-house modulation causes T2 blurring by limiting the number of slices and 2) a VFA scheme results in partial success with substantial SNR loss. In this work, accelerated GRASE with controlled T2 blurring is developed to enhance some extent unfold operate (PSF) and temporal signal-to-noise ratio (tSNR) with a large number of slices. Numerical and experimental studies had been performed to validate the effectiveness of the proposed method over common and VFA GRASE (R- and V-GRASE). The proposed technique, whereas reaching 0.8mm isotropic decision, useful MRI in comparison with R- and V-GRASE improves the spatial extent of the excited volume up to 36 slices with 52% to 68% full width at half most (FWHM) reduction in PSF but roughly 2- to 3-fold mean tSNR improvement, thus leading to greater Bold activations.